ORA-00106 cannot startup/shutdown database when connected to a dispatcher
Cause: An attempt was made to start or shut down an instance while
connected to a shared server via a dispatcher.
Action: Reconnect as user INTERNAL without going through the dispatcher.
For most cases, this can be done by connect to INTERNAL without specifying a
network connect string.
Cause: An attempt was made to start or shut down an instance while connected to a shared server via a dispatcher.
Action: Reconnect as user INTERNAL without going through the dispatcher. For most cases, this can be done by connect to INTERNAL without specifying a network connect string.