Forgings having recordable ultrasonic indications shall be referred to the purchaser and evaluated on the basis of nature, frequency, and locations of indications both traveling and stationary. If the ultrasonic indications are considered objectionable, it shall be determined by conventional or mutually acceptable inspection procedures whether the forging will be rejected.